TA45-2PA TA45-2PA - Thermal circuit breaker  1- or 2-pole with pushbutton actuation en IM0005420

Series: TA45-2PA

Circuit Breaker for Equipment thermal, 2 pole, Push button actuation, with auxiliary contact

Free Sample Request

Description

  • Thermal circuit breaker
  • 1 or 2 pole thermal overload protection
  • Positively trip-free release
  • High configurability
  • Snap-in or flange mounted
  • Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2)

Applications

  • Power tools
  • Industrial appliances
  • Power supplies

Rated Voltage AC

AC 240 VAC

Rated Voltage DC

60 VDC

Rated current range AC

0.05 - 20 A

Conditional short circuit capacity Inc

IEC: Inc, PC1, AC 240 V: 1 kA 

Degree of Protection

from front side IP40 acc. to IEC 60529

Dielectric Strength

4 kV

Insulation Resistance

500 VDC > 100 MΩ

Lifetime

mechanical: 50'000 switching cycles

AC: 1 x Ir:
50'000 switching cycles

DC: 1 x Ir:
50'000 switching cycles

Overload

AC: min. 40 trips
@ 6 x Ir

DC: min. 50 trips
@ 4 x Ir

Allowable Operation Temp.

-10 °C to 55 °C

Vibration Resistance

± 0.75 mm @ 5 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc

Shock Resistance

30 G / 18 ms
acc. to IEC 60068-2-27, test Ea

Tripping Type

Thermal 

Actuation Type

Pushbutton 

Weight

35 - 40 g

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: TA45

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number: 40019880
Approval marks cURus UL UL File Number: E71572
Approval marks ccc CCC CCC Certificate Number: 2013010307660082


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60934 Circuit-breakers for equipment (CBE)
Partners UL_Certification_Body Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment
Partners CSA_Certification_Body Designed according to CSA C22.2 No. 235 Supplementary Protectors
Partners CCC_Certification_Body Designed according to GB 17701 Circuit-breaker for equipment


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

Preview
 

Picture(s)

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Ordernumber
 

Ordernumber Unique part number for placing an order

Configuratietoets
 

Configuratietoets The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 

Comment CAD-tekeningen zijn alleen voor modelleerdoeleinden.

Model Description
 

Model Description

IGS
 

IGS

Step
 

Step

Parasolid
 

Parasolid

DXF
 

DXF

Dimension [mm]

Snap-in type and quick connect terminal with auxiliary contact

A) Quick connect terminal, IEC 61210, A6.3-0.8 mm

Snap-in type and screw clamp terminal with auxiliary contact

A) Quick connect terminal, DIN 46244, A6.3-0.8 mm
B) Screw type M3, 5x6 (Philips Form H),
maximum torque 1 Nm␉
Flange type and quick connect terminal with auxiliary contact

A) Quick connect terminal, IEC 61210, A6.3-0.8 mm

Flange type and screw clamp terminal with auxiliary contact

B) Screw type M3, 5x6 (Philips Form H),
maximum torque 1 Nm␉


Cut-out and pin-out

Cut-out snap-in type

1) Assemble
2) edge must be sharp
Cut-out flange type / Installation from rear

Cut-out flange type/ Installation from rear with AZZ05 cover

Pin-out

*) Auxiliary contact

Diagrams

1pole thermal overload protection, Auxiliary contact

1pole thermal overload protection, Auxiliary contact, Shunt terminal

2pole thermal overload protection, Auxiliary contact

2pole thermal overload protection, Auxiliary contact, Shunt terminal


Time-Current-Curves

Time in Seconds
Multiple of Rated Current In


Reference Temperature +23°
Time in Seconds
Multiple of Rated Current In


Reference Temperature +23°
Time in Seconds
Multiple of Rated Current In


Reference Temperature +23°

Effect of ambient temperature

Ambient Temperature [°C] Correction factor
-10 0.89
-5 0.91
0 0.92
+23 1.00
+30 1.03
+40 1.08
+55 1.16

Auxiliary contact (changeover)

Rated Voltage 28 VDC 60 VDC 240 VAC
Rated current max. 10 A resistive load max. 2 A resistive load max. 2 A cos φ 0.7

Short Table of Variants TA45-2PA Open complete table TA45-2PA

Thermal overload protection Addition connection type Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .
This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.
This approach offers to use generic alias link to the product details:
www.schurter.xx/art/ [Order Number]
where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:
- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle
Contact us for availability on other product variants, lead-times vary:
Contact-Form Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
               
 
1-pole Auxiliary contact Quick connect terminal 4430.1937 ...
Datum Subcategorie Taal Title Download
21/02/2019
White Paper Engels (English) White Paper Selecting rated currents for CBE
07/03/2017
PCN Engels (English) TA45 PCN
24/06/2016
PCN Engels (English) TA45 Rocker and Push Button, 2-, 3-Pole
Accessories (1)