Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
IEC C14 device plug with modular expandable components
Snap-in version
from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
IEC C14 device plug with modular expandable components
Snap-in version
from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
IEC C14 device plug with modular expandable components
Snap-in version
from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
IEC C14 device plug with modular expandable components
Snap-in version
from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
IEC C14 device plug with modular expandable components
Snap-in version
from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
IEC C14 device plug with modular expandable components
Snap-in version
from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side
Felcom 64  IEC C14 device plug with modular expandable components Snap-in version from front side

Series: Felcom 64

IEC Appliance Inlet C14 with modular extended Components

Free Sample Request

75 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C
F
Connector Logo
70° C

Description

  • Panel mount: Snap-in version, front side
  • 2 - 5 Functions: Appliance Inlet, Protection class I, Outlet, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1  or 2 pole, Solder terminals 3.5 x 0.8 mm / quick connect terminals 6.3 x 0.8 mm

Characteristics

  • Modular component selection
  • Individual components soldered on a printed circuit board
  • Plug removal necessary for fuse-link replacement
  • Fully insulated from the rear
  • Suitable for use in equipment according to IEC/UL 62368-1

Other versions on request

  • Line switch with other rocker marking

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

10 A / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

10 A / 250 VAC; 60 Hz

15 A / 250 VAC 60 Hz without fuse holder 

Allowable Operation Temperature

-25 °C to 70 °C

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.
The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects. Details about IP protection degree can be looked up in the general product information
IP-Protection

front side IP40 acc. to IEC 60529

Protection against electric shock

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.
The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects. Details about IP protection degree can be looked up in the general product information
IP-Protection

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.
Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

Solder terminals 3.5 x 0.8 mm / quick connect terminals 6.3 x 0.8 mm , tin-plated

Panel Thickness S

Panel Thickness S


See details in drawing
Snapper

Snap-in: 1/1.2/1.5/2/2.5/3 mm

Material: Housing

Thermoplastic, black, UL 94V-0

Appliance inlet/-outlet

Appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42
Details on connectors and their names can be found in the general product information
Appliance Couplers Mating Connectors Term explanation Special Connector Designs

C14 acc. to IEC 60320-1
and  F acc. to
UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Fuseholder

Fuseholder



1.) fuse holder does not include circuit breakers
2.) Details about fuse-links can be found in the catalog under
FusesDetailed information on the fuse holder and fuse drawers can be found in the general product information.
Fuse drawer

1-/2-pole, Shocksafe category PC2 acc. to IEC 60127-6,
for fuse-links 5 x 20 mm

Rated Power Acceptance @ Ta 23 °C

5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole

Power Acceptance @ Ta > 23°C

Admissible power acceptance at higher ambient temperature see derating curves

Line Switch

Line Switch


Also includes circuit breaker switch and switch for Bowden cables.

Details about the switches can also be found in the general product information.
Line Switch

Rocker switch 2-pole, non-illuminated, IEC 61058-1
Technical Details

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: Felcom 64

Approval Logo Certificates Certification Body Description
Approval marks ENEC_10 VDE Certificate Number: 40028094
Approval marks cURus UL UR File Number: E93617


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Approval marks IEC_Certification_Body Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Approval marks IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Approval marks UL Designed according to UL 60320-1 Standard for Attachment Plugs and Receptacles
Approval marks CSA_Certification_Body Designed according to CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC_Certification_Body Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements
Approval marks IEC_Certification_Body Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
Approval marks IEC_Certification_Body Suitable for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Glow_Wire_Proof SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 &-13.
Environment_Safety Medical SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

020050060000001118
LOADING...

Dimensions [mm]

Variants 6421.005X.XX
Mounting hole: 53.6+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 17.1 mm
A: Solder terminal 3.5x0.8 mm: 12.3 mm
Variants 6422.005X.XX
Mounting hole: 46.7+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm
A: Solder terminal 3.5x0.8 mm: 13.3 mm
S: Panel thickness␉
Variants 6423.0X5X.XX
Mounting hole: 65.5+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 18.15 mm
A: Solder terminal 3.5x0.8 mm: 13.35 mm␉
Variants 6424.0X5X.XX
Mounting hole: 57+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm
A: Solder terminal 3.5x0.8 mm: 13.3 mm
S: Panel thickness␉
Variants 6431.005X.XX
Mounting hole: 80.1 0/+0.2 x 27.6 0/+0.2
A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm
A: Solder terminal 3.5x0.8 mm: 13.3 mm
S: Panel thickness␉
1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts.
Variants 6432.0X5X.XX
Mounting hole: 90.6+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm
A: Solder terminal 3.5x0.8 mm: 13.3 mm
S: Panel thickness␉

Diagrams

6421

1) Load 2
2) Load 1
6422

1) Line
2) Load 1
6423

1) Load 2
2) Load 1
6424

1) Line
2) Load 1
6431

1) Load 2
2) Load 1
6432

1) Load 2
2) Load 1

Derating Curves

1-pole

Admissible power acceptance in Watt
Ambient air temperature Ta °C

2-pole

Admissible power acceptance in Watt per pole
Ambient air temperature Ta °C


Short Table of Variants Felcom 64 Open complete table Felcom 64

Type Connectors Connector Order Number
Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
 
Felcom 64 C14 - 6455.0051.15 ...
Felcom 64 C14 - 6422.0053.10 ...
Felcom 64 C14 - 6422.0053.12 ...
Felcom 64 C14 - 6422.0053.15 ...
Felcom 64 C14 - 6422.0053.20 ...
Felcom 64 C14 - 6422.0053.25 ...
Felcom 64 C14 - 6422.0053.30 ...
Felcom 64 C14 - 6422.0051.12 ...
Felcom 64 C14 - 6422.0051.15 ...
Felcom 64 C14 - 6424.0153.10 ...
Felcom 64 C14 - 6424.0153.12 ...
Felcom 64 C14 - 6424.0153.15 ...
Felcom 64 C14 - 6424.0153.20 ...
Felcom 64 C14 - 6424.0153.25 ...
Felcom 64 C14 - 6424.0153.30 ...
Felcom 64 C14 - 6424.0151.10 ...
Felcom 64 C14 - 6424.0151.12 ...
Felcom 64 C14 - 6424.0151.15 ...
Felcom 64 C14 - 6424.0151.20 ...
Felcom 64 C14 - 6424.0151.30 ...
Felcom 64 C14 - 6424.0253.10 ...
Felcom 64 C14 - 6424.0253.12 ...
Felcom 64 C14 - 6424.0253.15 ...
Felcom 64 C14 - 6424.0253.20 ...
Felcom 64 C14 - 6424.0253.25 ...
Felcom 64 C14 - 6424.0253.30 ...
Felcom 64 C14 - 6424.0251.10 ...
Felcom 64 C14 - 6424.0251.12 ...
Felcom 64 C14 - 6424.0251.15 ...
Felcom 64 C14 - 6424.0251.20 ...
Felcom 64 C14 - 6424.0251.25 ...
Felcom 64 C14 - 6424.0251.30 ...
Felcom 64 C14 - 6424.0250.30 ...
Felcom 64 C14 F 6421.0053.12 ...
Felcom 64 C14 F 6421.0053.15 ...
Felcom 64 C14 F 6421.0053.20 ...
Felcom 64 C14 F 6421.0053.25 ...
Felcom 64 C14 F 6421.0053.30 ...
Felcom 64 C14 F 6421.0051.10 ...
Felcom 64 C14 F 6423.0153.12 ...
Felcom 64 C14 F 6423.0153.15 ...
Felcom 64 C14 F 6423.0153.20 ...
Felcom 64 C14 F 6423.0151.15 ...
Felcom 64 C14 F 6423.0151.25 ...
Felcom 64 C14 F 6423.0151.30 ...
Felcom 64 C14 F 6423.0253.10 ...
Felcom 64 C14 F 6423.0253.15 ...
Felcom 64 C14 F 6423.0253.20 ...
Felcom 64 C14 F 6423.0253.30 ...
Felcom 64 C14 F 6423.0251.15 ...
Felcom 64 C14 F 6423.0251.25 ...
Felcom 64 C14 F 6423.0251.30 ...
Felcom 64 C14 F 6431.0053.15 ...
Felcom 64 C14 F 6431.0053.20 ...
Felcom 64 C14 F 6431.0053.30 ...
Felcom 64 C14 F 6431.0051.10 ...
Felcom 64 C14 F 6431.0051.15 ...
Felcom 64 C14 F 6431.0051.20 ...
Felcom 64 C14 F 6431.0051.25 ...
Felcom 64 C14 F 6432.0153.10 ...
Felcom 64 C14 F 6432.0153.15 ...
Felcom 64 C14 F 6432.0153.20 ...
Felcom 64 C14 F 6432.0153.25 ...
Felcom 64 C14 F 6432.0153.30 ...
Felcom 64 C14 F 6432.0151.15 ...
Felcom 64 C14 F 6432.0253.10 ...
Felcom 64 C14 F 6432.0253.12 ...
Felcom 64 C14 F 6432.0253.15 ...
Felcom 64 C14 F 6432.0253.20 ...
Felcom 64 C14 F 6432.0253.30 ...
Felcom 64 C14 F 6432.0251.10 ...
Felcom 64 C14 F 6432.0251.15 ...
Felcom 64 C14 F 6432.0251.20 ...
Felcom 64 C14 F 6432.0251.30 ...
Felcom 64 C14 F 6432.0250.25 ...

Packaging unit 10 Pcs 

020050060000001118
LOADING...
Alternative: version with line filter (1)

[Swipe to the left and right for more options]

Mating Inlets/Plugs (5)

[Swipe to the left and right for more options]

4732

4732, Mounting: Power Cord, Plug: IEC E, Cable

4735

4735, Mounting: Power Cord, Plug: IEC E, Cable

9009

9009, Mounting: Plug: IEC E, Screw clamps

4733

4733, Mounting: Power Cord, Plug: IEC E, Cable

4736

4736, Mounting: Power Cord, Plug: IEC E, Cable

Mating Outlets/Connectors (7)

[Swipe to the left and right for more options]

4787

4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

4781 Mounting: Power Cord, Cable, Connector: IEC C15

4784

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

Accessories (1)

[Swipe to the left and right for more options]

Cord retaining kits

Cord retaining strain relief


25.09.2024
   