SKD 160A  SKD house connection box 160A
SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD 160A  SKD house connection box 160A
SKD 160A  SKD house connection box 160A

Series: SKD 160A

SKD house connection box 160A, DIN 00 (gG)

Free Sample Request

8 Variants


Description

  • Glass fiber Polyester
  • Difficult to burn
  • Impact resistant IK07 (2J)
  • Outside earth permanently mounted
  • For indoor and outdoor
  • For fixed installation

Unique Selling Proposition

  • Additional protection covers for double terminal Woertz
  • NH fuse-links with prisms + neutral disconnector with straps, input side (4-wire system), tested for aluminium cable
  • With 1 x 3 pole fuse switch disconnector
  • Prepared for 3 x 1 pole power circuit breakers

Characteristics

  • With 3 x 1-pole fuse switch disconnector
  • Wide range of accessories
  • Mounting and connection convenience thanks two-piece housing
  • Bolt lock (4-kant with Slot)
  • Protection 2-piece snap, transparent and sealable
  • N-connector for TN-C to TN-S
  • N-connector separating Piece self-opening when loosening the screw
  • Voltage test possible only if fuse with not insulated straps used
  • Earthing clamp for max 95mm² copper cable

The fresh design and the strikingly smaller installation depth of 2 cm immediately attract attention the first time you look at the house connection box. The new interior is protected by the cover with a square bolt lock with slot. The internal contact protection of the SKD house connection box is provided by snap-on, transparent and lockable inner covers, which can be removed without tools. Of course, the SKD house connection box is also well prepared for the future of the grid. The SKD is also equipped for 3-pole switching elements or 1-pole high-performance automatic switches. (3)

[Swipe to the left and right for more options]

The inlet and outlet covers can be easily sealed.

Cover panels

NH fuses Voltage testing of NH fuses with non-insulated handles possible through hinged window

Rated Current Ie

160 A  @  500 VAC

125 A␠ @  690 VAC

Rated voltage Ue

690 VAC

Rated isolation voltage Ui

1000 VAC

Rated Power Operating Frequency fe

50 Hz

Rated diversity factor RDF

0.70 

NH-Fuse-Link with Screw Terminal for Cable Log

M8 

NH-Fuse-Link with Prisms

6  -  95 mm²

Fuse-Link

DIN 00 

Rated Current Ie

160 A  @  500 VAC

125 A␠ @  690 VAC

Rated voltage Ue

690 VAC

220 VDC

Rated isolation voltage Ui

1000 VAC

Rated Power Operating Frequency fe

50 Hz

Rated Impulse Withstand Voltage Uimp

8 kV

Conditioned Rated Short Cicuit Current

80 kA␠ @  500 VAC

50 kA␠ @  690 VAC

␠ 

Rated Impulse Withstand Voltage Uimp

8 kV

Conditioned Rated Short Cicuit Current

50 kA  @  690 VAC

80 kA␠ @  500 VAC

Rated short-time withstand current with fuse links

20 kA␠ @  500 VAC

Allowed Ambient Temperature

-25 °C to +40 °C acc. to IEC 61439

Protection by closed housing

IP54 acc. to IEC 60529

Pollution Degree

Neutral Disconnector with Straps

6   - 95 mm²

Earth Connection Bride

6  -  95 mm²

Double erminal

6  -  50 mm²

Earth Connection

6  -  50 mm²

Earth Connection (outside)

M8 

Category of use AC

AC-23B  @  400 VAC

AC-22B  @  500 VAC

AC-21B  @  690 VAC

Category of use DC

DC-22B  @  220 VDC

Rated power dissipation with-out NH fuse-links at Ith

2.3 W

Protection class

IP20 

Mechanical lifetime

1400  Insertions​

Electrical lifetime

200  Insertions​

Ambient Temperature Tu**)

-40 °C to +55 °C

Prisma strap: radius small 6 - 25 mm² / radius big 35 - 95 mm²

**) A reduction of the rated current is required above 30°C

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in   Details about Approvals


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: SKD 160A

Approval Logo Certificates Certification Body Description
Approval marks CoC CERTIFEL Eurofins Certificate Number: IK-4271


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

900150030000005521
LOADING...

Dimensions [mm]


Assembly Instructions

1. two-part cover plates, snapped, transparent and sealable
2. NH fuse switch disconnectors
3. hinged window
4. internal covers
5. different connection variants- Prismabride- Cable lug M8- Double terminals
6. Square lock
7. marking strips
8. neutral conductor isolator for TN-S/TN-C
9. external ground connection permanently mounted
10. Earth bracket (optional)
11. expansion module with DIN rail (optional)
12. 63A- Fuse element with touch protection and various connection variants


Diagrams

TN-S (delivered condition)

L = Pole conductor
PE = Protective conductorPEN = PEN conductor
N = Neutral conductor
NE = Neutral earth conductor
TS = Separating screw
KA = Cable armor
TN-C

L = Pole conductor
PE = Protective conductorPEN = PEN conductor
N = Neutral conductor
NE = Neutral earth conductor
TS = Separating screw
KA = Cable armor

All SKD house connection boxes from SCHURTER AG are equipped with the versatile neutral conductor isolator. The neutral conductor isolator is suitable for use in networks with earthing according to the TN-S and TN-C diagrams. The connection type can be changed by simply repositioning the separating screw.


Short Table of Variants SKD 160A Open complete table SKD 160A

Designation Equipped Terminal E-No. A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:
- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle
Contact us for availability on other product variants, lead-times vary:
Contact-Form Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
 
SKD 160A DIN00+0+E - Screw connection M8 827255028  A  ...
SKD 160A DW DIN00+0+E - Double Terminal 827255038  A  ...
SKD 160A DIN00+0+E - Prisms strap 827255028  A  ...
SKD 160A DIN00+0+E Cable bride 1 x 38 mm, Rubber, Cover 1 x M40 Prisms strap 827255068  A  ...
SKD 160A DIN00+0+E Cable bride 1 x 38 mm, Rubber, Cover 1 x M40 + 1 x M16 Prisms strap 827255058  A  ...
SKD 160A DIN00+0+E Cable bride 1 x 38 mm, Rubber, Cover 1 x M50 + 1 x M16 Prisms strap 827255048  A  ...
SKD 160A 3P DIN00+0+E - Prisms strap ¹⁾  A  ...
SKD LS+0+E - - ²⁾  A  ...

Most Popular.

¹⁾ 1 x 3 pole fuse switch disconnector

²⁾ without power circuit breakers

Packaging unit 1 Pcs 

900150030000005521
LOADING...
Alternative: Other rated current (1)

[Swipe to the left and right for more options]

Accessories (10)

[Swipe to the left and right for more options]

Cover Plates 160A

Cover Plates for SKD 160A

Fuse element 160A

Fuse Element for SKD 160A

Screw Connection

Screw Connection for Fuse Element 160A

Terminal Cover

Terminal cover for SKD 25A, 63A and 160A

Covers SKD 25/60/160 A

Covers for SKD 25A, 63A and 160A

Cable Bride

Cable Bride for SKD 25A, 63A and 160A

Rubber

Rubber for SKD 25A, 63A and 160A

Expansion Module

Expansion Module for SKD 25A, 63A and 160A

Earth Clip

Earth Clip for SKD 25A, 63A and 160A

N-Conductor

N-Conductor for SKD 25A, 63A and 160A


23.08.2023
   
nl prod Door de catalogusversie te veranderen (Desktop <> Mobiel), stelt het systeem de gekozen filters opnieuw in.